400kW Silent-Type & Open-Type Diesel Generator Set

The 400kW Cummins diesel generator set is designed for industrial facilities, engineering projects, and large commercial applications requiring reliable medium-to-high capacity power supply.

Powered by a Cummins diesel engine and equipped with an industrial alternator and advanced control system, the 400kW generator set provides dependable power support for standby, prime power, and customized energy solutions.

Main technical parameters

Unit Parameters
Generator Set ModelHL400GF
Output Prime/Standby Capacity (kVA)500/550
Output Prime/Standby Power (kW)400/440
Output Prime/Standby Current (A)720/792Output Voltage (V)400/230
Frequency (Hz)50Power Factor0.8 Lag
Number of phases and wiring systemThree-phase four-wire systemVoltage AdjustmentAutomatic Constant Voltage System
Voltage testThree-phase detectionCurrent TestThree-phase Sensing
Steady-state voltage regulation rate≤±1.0%Steady-state frequency regulation rate≤±0.5%
Steady-state voltage fluctuation rate≤±0.5%Steady-state frequency fluctuation rate≤±0.5%
Transient voltage regulation rate-0.35Transient frequency regulation rate-0.17
Voltage stabilization time≤1SFrequency stabilization time≤3S
Voltage setting rise range≥5.0%Voltage adjustment (downward) range≤-5.0%
Frequency drop≤3.0%Connection methodInternationally standard SAE flexible connection
Power transmission methodManual
Waveform distortionSine wave, waveform distortion <5%
Radio interference suppression performanceTelephone Influence Factor (TIF) < 50, Telephone Harmonic Factor (THF) < 2%
Operating EnvironmentAmbient temperature ≤ 40°C, altitude ≤ 1000m, relative humidity ≤ 60%
Compliance with StandardsComplies with GB/T 2820-2009
Diesel Engine
ModelQSZ13-G10Power (kW)463/509
ManufacturerCummins Powertrain Technologies Co., Ltd.
Engine ConfigurationInline, 6-cylinder, four-stroke, turbocharged, air-to-air intercooled
Bore × Stroke (mm)130×163Rotational speed Rpm/min1500
Displacement (L)13Speed control methodElectronic speed control
Starting method24V DC startingCooling methodClosed-loop water-cooled air circulation system
Fuel consumption rate (100%) (g/kW·h)≤191Compression ratio17:01
Filtration systemFeatures integrated replacement units for engine oil, diesel, and air filters.
Exhaust systemEquipped with an industrial-grade muffler offering high noise-reduction performance.
Dynamo
ModelS5L1D-C41
ManufacturerCummins Generator Technologies (China) Co., Ltd.
Structure and excitation methodBrushless, self-excited, self-cooling, and constructed with pure copper windings.
Rated capacity (kVA)500Rated Power (kW)400
Protection classIP21Insulation ClassH
Number of poles4 polesEfficiency98.30%
No-load voltage adjustment range≥±5%Voltage Control MethodAVR Automatic voltage regulation
Voltage recovery time<1 secondFrequency Fluctuation Rate≤±0.25%
Overload capacity and duration10%; 1 hour allowed within 12 hours.
Control Panel
ModelHLK400
Monitoring ItemCurrent, voltage, frequency, oil pressure, water temperature, rotational speed, etc.

Product Positioning

A Professional Power Solution for Industrial Facilities and Project Applications

It is commonly selected when the project requires:

  • Higher load capacity
  • Support for multiple electrical systems
  • Reliable operation of industrial equipment
  • Flexible installation options
  • Long-term operational stability

Compared with 200kW generator sets, the 400kW class provides greater capacity for larger facilities and more complex load conditions.

Compared with 500kW and larger generator systems, the 400kW generator offers a practical balance between power capability, equipment investment, installation requirements, and maintenance convenience.

Procurement Considerations Before Ordering

For a 400kW Cummins generator project, you should provide detailed technical information.

1. Electrical Load Information

Recommended information:

  • Total load capacity
  • Running power
  • Starting power
  • Motor quantity
  • Motor starting method
  • Load priority

Especially for applications with:

  • Pumps
  • Compressors
  • Motors
  • Heavy machinery

the starting characteristics should be evaluated before generator selection.

2. Operating Requirements

You should confirm:

  • Standby or prime power
  • Expected operating hours
  • Continuous or intermittent operation
  • Required redundancy level

3. Installation Conditions

Important  information:

  • Indoor or outdoor installation
  • Ambient temperature
  • Altitude
  • Space limitations
  • Noise requirements
  • Fuel storage conditions

Why Choose a 400kW Cummins Generator Set?

Suitable for Industrial Load Requirements

The 400kW class provides sufficient capacity for many medium and large industrial applications.

Better Adaptability to Complex Loads

Suitable for facilities containing:

  • Motors
  • Pumps
  • Compressors
  • Production equipment

Designed for Project-Based Applications

The 400kW generator set is suitable for users who need engineering support rather than a standard equipment purchase only.

Before Requesting a Quotation

To recommend a suitable 400kW Cummins diesel generator set, please provide:

  • Application type
  • Required power capacity
  • Voltage and frequency
  • Load list
  • Motor starting information
  • Installation environment
  • Noise requirements
  • Quantity required
  • Parallel operation requirements